EN 14122-3 PDF

This revised standard defines the requirements for safe access to machines, applying to both stationary and mobile machinery where a fixed means of access is necessary. The standard specifies that when the height of a fall could exceed mm, a guard-rail should be installed, and the chosen system needs to meet several dimensional requirements. It also notes that a self-closing gate should be used. Maintenance and inspection teams require safe protection to openings such as on work platforms, around industrial machinery or as part of demarcation routes in warehouse and logistic centres, in addition to providing safe access and egress for ladders, walkways and rooftop guardrails. For many years, chains, bars and sliding link tubes have been the method of protection for safe access. Now, with this standard, there is a very clear set of requirements and dimensions for safety gates.

Author:Shakanris Akinotaur
Country:Sri Lanka
Language:English (Spanish)
Genre:Education
Published (Last):2 October 2005
Pages:168
PDF File Size:14.5 Mb
ePub File Size:9.85 Mb
ISBN:987-5-54509-363-4
Downloads:98865
Price:Free* [*Free Regsitration Required]
Uploader:Keshicage



This revised standard defines the requirements for safe access to machines, applying to both stationary and mobile machinery where a fixed means of access is necessary. The standard specifies that when the height of a fall could exceed mm, a guard-rail should be installed, and the chosen system needs to meet several dimensional requirements.

It also notes that a self-closing gate should be used. Maintenance and inspection teams require safe protection to openings such as on work platforms, around industrial machinery or as part of demarcation routes in warehouse and logistic centres, in addition to providing safe access and egress for ladders, walkways and rooftop guardrails.

For many years, chains, bars and sliding link tubes have been the method of protection for safe access. Now, with this standard, there is a very clear set of requirements and dimensions for safety gates.

The system should incorporate a knee rail that is mm from the top rail, and a lower bottom rail that is no more than mm from the floor level. The standard also states that the gate should not be locked, but held in closed position, and should be designed to open easily and closed with a firm stop, preventing users pushing against the gate and potentially falling through the opening.

Both promote self-closing gates as the preferred method of protection because they automatically close behind the user to provide an added level of security, so overcoming the potential for human error.

Available with standard 'U' bolts for fixing to uprights of An additional fixing pack is provided which allows the gate to be fixed to square, flat or angle uprights. Designed to be trimmed on-site, this solution saves companies the time and money it takes to fabricate their own gates. Specifying a self-closing gate that is in line with the requirements set out in EN ISO , presents contractors with a quicker, more cost-effective and easier to install solution that eliminates the possibility of human error.

Contact us to discuss your project details today! Kee Safety Ltd. Welcome to the Rooftop Report - A podcast produced by KeeSafety focused on providing you with the knowledge and ex… twitter.

We are dedicated to providing the highest level of safety when working at height. For any queries you can email us… twitter. Falls from height can be easily prevented by taking simple steps, such as assessing risks, planning work, and using… twitter. Now is a good time educate yourself on working at height safety measures, such as the importance of correctly asse… twitter. Keep up to date with us on our YouTube channel for product demos and more youtube.

Visit our Knowledge Centre to find out more about us and what we offer, as well as all the fallprotection informat… twitter. Important updates to the EN standard. Safe protection to openings Maintenance and inspection teams require safe protection to openings such as on work platforms, around industrial machinery or as part of demarcation routes in warehouse and logistic centres, in addition to providing safe access and egress for ladders, walkways and rooftop guardrails.

Updated standard requirements The system should incorporate a knee rail that is mm from the top rail, and a lower bottom rail that is no more than mm from the floor level.

Older Story Newer Story.

CASIO XJ H2650 PDF

ISO 14122-3:2016

This is Part 3 in a series of four international standardswhich define general requirements for safe access to machinery. This part of BS EN ISO gives requirements for non-powered stairs, stepladders and guard-rails which are a part of a stationary machine, and to the non-powered adjustable parts e. It specifies minimum requirements that also apply when the same means of access is required as the part of the building or civil construction e. Multi-user access to over 3, medical device standards, regulations, expert commentaries and other documents. Worldwide Standards We can source any standard from anywhere in the world.

NEDOKONCENE PRIBEHY TOLKIEN PDF

DIN EN ISO 14122-3:2016-10

We use cookies to make our websites more user-friendly and to continuously improve them. If you continue to use the website, you consent to the use of cookies. You can find more information in our privacy statement and our cookie guidelines. These cookies are essential for the operation of the site and enable, for example, security-relevant functions. In addition, we can also use this type of cookie to determine whether you want to remain logged in to your profile in order to make our services available to you more quickly when you visit our website again. In order to further improve our offer and our website, we collect anonymized data for statistics and analysis. With the help of these cookies we can, for example, determine the number of visitors and the effect of certain pages on our website and optimize our content.

Related Articles